Standards catalogue

ISO/TC 92/SC 1

Fire initiation and growth

  • Filter:
  •  
  •  
  •  
  •  
Standard and/or project under the direct responsibility of ISO/TC 92/SC 1 Secretariat Stage ICS
ISO 1182:1983 [Withdrawn]
Fire tests -- Building materials -- Non-combustibility test
95.99
ISO 1182:1990 [Withdrawn]
Fire tests -- Building materials -- Non-combustibility test
95.99
ISO 1182:2002 [Withdrawn]
Reaction to fire tests for building products -- Non-combustibility test
95.99
ISO 1182:2010
Reaction to fire tests for products -- Non-combustibility test
90.92
ISO/CD 1182 [Under development]
Reaction to fire tests for products -- Non-combustibility test
30.20
ISO 1716:2002 [Withdrawn]
Reaction to fire tests for building products -- Determination of the heat of combustion
95.99
ISO 1716:2010
Reaction to fire tests for products -- Determination of the gross heat of combustion (calorific value)
90.92
ISO/FDIS 1716 [Under development]
Reaction to fire tests for products -- Determination of the gross heat of combustion (calorific value)
50.00
ISO/TR 3814:1989 [Withdrawn]
Tests for measuring "reaction-to-fire" of building materials -- Their development and application
95.99
ISO/TS 3814:2014
Standard tests for measuring reaction-to-fire of products and materials -- Their development and application
90.93
ISO 5657:1986 [Withdrawn]
Fire tests -- Reaction to fire -- Ignitability of building products
95.99
ISO 5657:1997
Reaction to fire tests -- Ignitability of building products using a radiant heat source
90.93
ISO/TR 5657:1982 [Withdrawn]
Fire tests -- Reaction to fire -- Ignitability of building products
95.99
ISO/TR 5658-1:1997 [Withdrawn]
Reaction to fire tests -- Spread of flame -- Part 1: Guidance on flame spread
95.99
ISO/TS 5658-1:2006
Reaction to fire tests -- Spread of flame -- Part 1: Guidance on flame spread
90.93
ISO 5658-2:1996 [Withdrawn]
Reaction to fire tests -- Spread of flame -- Part 2: Lateral spread on building products in vertical configuration
95.99
ISO 5658-2:2006
Reaction to fire tests -- Spread of flame -- Part 2: Lateral spread on building and transport products in vertical configuration
90.93
60.60
ISO 5658-4:2001
Reaction to fire tests -- Spread of flame -- Part 4: Intermediate-scale test of vertical spread of flame with vertically oriented specimen
90.93
ISO 5660-1:1993 [Withdrawn]
Fire tests -- Reaction to fire -- Part 1: Rate of heat release from building products -- (Cone calorimeter method)
95.99
95.99
ISO 5660-1:2002 [Withdrawn]
Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 1: Heat release rate (cone calorimeter method)
95.99
ISO 5660-1:2015
Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)
60.60
ISO 5660-2:2002 [Withdrawn]
Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 2: Smoke production rate (dynamic measurement)
95.99
ISO/TR 5660-3:2003 [Withdrawn]
Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 3: Guidance on measurement
95.99
ISO/TS 5660-3:2012
Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 3: Guidance on measurement
90.93
ISO 5660-4:2008 [Withdrawn]
Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 4: Measurement of heat release for determination of low levels of combustibility
95.99
ISO/TS 5660-4:2016
Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 4: Measurement of low levels of heat release
60.60
ISO/CD 5660-5 [Under development]
Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 5: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) under oxygen reduced atmospheres
30.60
ISO/TR 5924:1989 [Withdrawn]
Fire tests -- Reaction to fire -- Smoke generated by building products (dual-chamber test)
95.99
ISO 9239-1:1997 [Withdrawn]
Reaction to fire tests -- Horizontal surface spread of flame on floor-covering systems -- Part 1: Flame spread using a radiant heat ignition source
95.99
95.99
95.99
ISO 9239-1:2002 [Withdrawn]
Reaction to fire tests for floorings -- Part 1: Determination of the burning behaviour using a radiant heat source
95.99
ISO 9239-1:2010
Reaction to fire tests for floorings -- Part 1: Determination of the burning behaviour using a radiant heat source
90.93
ISO 9239-2:2002
Reaction to fire tests for floorings -- Part 2: Determination of flame spread at a heat flux level of 25 kW/m2
90.93
ISO 9705:1993 [Withdrawn]
Fire tests -- Full-scale room test for surface products
95.99
95.99
ISO 9705-1:2016
Reaction to fire tests -- Room corner test for wall and ceiling lining products -- Part 1: Test method for a small room configuration
60.60
ISO/TR 9705-2:2001
Reaction-to-fire tests -- Full-scale room tests for surface products -- Part 2: Technical background and guidance
90.93
ISO/TR 11696-1:1999
Uses of reaction to fire test results -- Part 1: Application of test results to predict fire performance of internal linings and other building products
90.93
ISO/TR 11696-2:1999
Uses of reaction to fire test results -- Part 2: Fire hazard assessment of construction products
90.93
ISO/TR 11925-1:1999
Reaction to fire tests -- Ignitability of building products subjected to direct impingement of flame -- Part 1: Guidance on ignitability
90.93
ISO 11925-2:1997 [Withdrawn]
Reaction to fire tests -- Ignitability of building products subjected to direct impingement of flame -- Part 2: Single flame source test
95.99
95.99
ISO 11925-2:2002 [Withdrawn]
Reaction to fire tests -- Ignitability of building products subjected to direct impingement of flame -- Part 2: Single-flame source test
95.99
ISO 11925-2:2010
Reaction to fire tests -- Ignitability of products subjected to direct impingement of flame -- Part 2: Single-flame source test
90.92
60.60
ISO/NP 11925-2 [Under development]
Reaction to fire tests -- Ignitability of products subjected to direct impingement of flame -- Part 2: Single-flame source test
10.99
ISO 11925-3:1997
Reaction to fire tests -- Ignitability of building products subjected to direct impingement of flame -- Part 3: Multi-source test
90.93
60.60
ISO 12136:2011
Reaction to fire tests -- Measurement of material properties using a fire propagation apparatus
90.93
ISO 12863:2010
Standard test method for assessing the ignition propensity of cigarettes
90.92
60.60
60.60
ISO 12949:2011
Standard test method for measuring the heat release rate of low flammability mattresses and mattress sets
90.93
ISO 13784-1:2002 [Withdrawn]
Reaction-to-fire tests for sandwich panel building systems -- Part 1: Test method for small rooms
95.99
ISO 13784-1:2014
Reaction to fire test for sandwich panel building systems -- Part 1: Small room test
60.60
ISO 13784-2:2002
Reaction-to-fire tests for sandwich panel building systems -- Part 2: Test method for large rooms
90.93
ISO 13785-1:2002
Reaction-to-fire tests for façades -- Part 1: Intermediate-scale test
90.93
ISO 13785-2:2002
Reaction-to-fire tests for façades -- Part 2: Large-scale test
90.92
ISO/NP 13785-2 [Under development]
Reaction-to-fire tests for façades -- Part 2: Large-scale test
10.99
ISO 14696:2009
Reaction-to-fire tests -- Determination of fire and thermal parameters of materials, products and assemblies using an intermediate-scale calorimeter (ICAL)
90.93
ISO/TR 14696:1999 [Withdrawn]
Reaction to fire tests -- Determination of fire parameters of materials, products and assemblies using an intermediate-scale heat release calorimeter (ICAL)
95.99
ISO 14697:2007
Reaction-to-fire tests -- Guidance on the choice of substrates for building and transport products
90.92
ISO/NP 14697 [Under development]
Reaction-to-fire tests -- Guidance on the choice of substrates for building and transport products
10.99
ISO/TR 14697:1997 [Withdrawn]
Fire tests -- Guidance on the choice of substrates for building products
95.99
ISO 14934-1:2010
Fire tests -- Calibration and use of heat flux meters -- Part 1: General principles
90.93
ISO/TS 14934-1:2002 [Withdrawn]
Fire tests -- Calibration and use of radiometers and heat flux meters -- Part 1: General principles
95.99
ISO 14934-2:2006 [Withdrawn]
Fire tests -- Calibration and use of heat flux meters -- Part 2: Primary calibration methods
95.99
ISO 14934-2:2013
Fire tests -- Calibration and use of heat flux meters -- Part 2: Primary calibration methods
60.60
ISO 14934-3:2006 [Withdrawn]
Fire tests -- Calibration and use of heat flux meters -- Part 3: Secondary calibration method
95.99
ISO 14934-3:2012
Fire tests -- Calibration and use of heat flux meters -- Part 3: Secondary calibration method
90.93
ISO 14934-4:2014
Fire tests -- Calibration and use of heat flux meters -- Part 4: Guidance on the use of heat flux meters in fire tests
60.60
ISO/TS 14934-4:2007 [Withdrawn]
Fire tests -- Calibration of heat flux meters -- Part 4: Guidance on the use of heat flux meters in fire tests
95.99
ISO 16405:2015
Room corner and open calorimeter -- Guidance on sampling and measurement of effluent gas production using FTIR technique
60.60
ISO/NP TR 17252 [Under development]
Fire tests -- Applicability of reaction to fire tests to fire modelling and fire safety engineering
10.99
ISO/TR 17252:2008
Fire tests -- Applicability of reaction to fire tests to fire modelling and fire safety engineering
90.92
ISO/TS 17431:2006
Fire tests-- Reduced-scale model box test
90.93
ISO 17554:2005 [Withdrawn]
Reaction to fire tests -- Mass loss measurement
95.99
ISO 17554:2014
Reaction to fire tests -- Mass loss measurement
60.60
ISO/DTS 19021 [Under development]
Test method for determination of gas concentrations in ISO 5659-2 using Fourier transform infrared spectroscopy
30.60
ISO/NP TS 19850 [Under development]
Fire tests -- method for evaluating the potential use of LED (light emitting diode) as alternative to white light for measuring the smoke density and smoke production rate in fire test
10.99
ISO 20632:2008
Reaction-to-fire tests -- Small room test for pipe insulation products or systems
90.93
ISO/AWI 21397 [Under development]
FTIR analysis of fire effluents in cone calorimeter tests
20.00
ISO/TS 22269:2005
Reaction to fire tests -- Fire growth -- Full-scale test for stairs and stair coverings
90.93
ISO 24473:2008
Fire tests -- Open calorimetry -- Measurement of the rate of production of heat and combustion products for fires of up to 40 MW
90.93
ISO 29473:2010
Fire tests -- Uncertainty of measurements in fire tests
90.93

No matching records found