This document describes the following:

—    a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements;

NOTE 1   For the background interlaboratory study used to verify the test methodology, see Annex D.

—    a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics;

—    a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≥ 25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L;

NOTE 2   It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.

—    a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with Annex A.

This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.

This document applies to three test conditions:

—    test condition 1, with a base upstream gravimetric level of 3 mg/L;

—    test condition 2, with a base upstream gravimetric level of 10 mg/L;

—    test condition 3, with a base upstream gravimetric level of 15 mg/L.


Общая информация

  • Текущий статус :  Published
    Дата публикации : 2022-01
  • Версия : 3
  • :
    ISO/TC 131/SC 6
    Contamination control
  • 23.100.60
    Filters, seals and contamination of fluids

Приобрести данный стандарт

Формат Язык
PDF + ePub
Бумажный
  • CHF158

Жизненный цикл


Появились вопросы?

Ознакомьтесь с FAQ

Работа с клиентами
+41 22 749 08 88

Часы работы:
Понедельник – пятница: 09:00-12:00, 14:00-17:00 (UTC+1)

Будьте в курсе актуальных новостей ИСО

Подписывайтесь на наши новости, обзоры, а также на информацию о продуктах.